STANDARD

IS 9000

BASIC ENVIRONMENTAL TESTING PROCEDURES

MAIN TESTS

  1. COLD TEST
  2. DRY HEAT
  3. DAMP HEAT (CYCLIC AND STEADY)
  4. VIBRATION
  5. THERMAL CYCLING
  6. THERMAL SHOCK

TESTING RANGE

MULTIPLE CHAMBERS AND EQUIOMENTS FOR SPECIFIC TESTS

  1. Temperature Range: 0C to -45 °C, Max. ramp rate:5 °C/minute, Chamber Size: 900mmx900mmx900mm
  2. Temperature Range: Ambient to 250 °C, Max. ramp rate:5 °C/minute, Chamber Size: 900mmx900mmx900mm
  3. Temperature Range: ambient  to 60 °C & Upto 95 % Humidity, Chamber Size: 2 mx1.5 mx 1.5 m
  4. Vibration Test: 5 Hz to 3200 Hz, 90 `g’ (Sine), X, Y, Z Axis, Max. velocity 1.7m/sec For Shock test: 0.1g to 90g, 20mS, X, Y, Z Axis, Weight Capacity: 0.1g to 100 kg